Thursday, December 19, 2013

An Ounce of Prevention

Decon-what?


It was one of those small rural hospitals with big eyes and a small wallet.  Each year they gave in to optimism and asked for a quote and each year I gave one and crossed my fingers.

Then came new ownership and an influx of cash. I responded to the call for a quote and examined their needs, wants, available floor space and utilities. During this process, I also examined the instrument washer they wanted to keep in place. It was an ancient model, likely among the first 444s to roll off Amsco’s assembly line.

Among its deficiencies, the washer did not include a drying unit, so the instruments came out of the washer as if the surgeon had just stepped out of the shower with them. The unit featured only one chemical pump, limiting the ability to pre-clean with an enzymatic detergent and lubricate instruments in the final stages.

But the most startling discovery was the condition of the washer’s interior. It was blacker than a coal miner’s boots. My gasp upon opening the door was audible.
“When was the last time you ran a decontam cycle on this washer?” I asked a passing technician, in the most non-judgmental tone I could muster.

“Run a what?”

“A decontam cycle. To clean the inside of the washer.”
“I don’t know what you’re talking about,” was her reply.
I led her gently to the washer and pointed to the button labeled Decontam.

“We don’t use that,” she said.
“Okaaaay,” said I. “Do you have any descaler around?”
“We may have something here for the autoclave,” she said and led me to a counter.
Stooped and peering into the cabinet beneath the counter, we rummaged around until we found a jug of autoclave cleaner in the very back. It was sold by Castle (now Getinge), one of my competitors, yet there was no Castle equipment in house. It’s age was indeterminate, yet it bore the magic ingredient on the label – phosphoric acid.

The tech had, by this time, disappeared, so I began a decontam cycle on my own. I opened the door and added the descaler. The drain began to hiss and a thin spiral of vapor rose out of the drain

“Uh oh,” I thought as the door closed and the decontam cycle began.

I spent the next 40 minutes taking measurements and examining utilities, all the while turning casually to the washer and peeking in through the glass.

At last the washer signaled that the cycle was finished. I took a deep breath and opened the door. The inside was as bright and shiny as an uncirculated dime. The blinding gleam coming from the interior fairly shouted confidence in a rejuvenated ability to clean.

I grabbed the disinterested technician, and every other tech I could find, and hauled them over to the washer. Then, taking her by the ear, I led the director of sterile processing to the unit and we all marveled at the transformation within. We performed an impromptu in-service on the decontam cycle and stressed the importance of making it a routine practice.

It is my hope that this did, indeed, become a routine practice. It should be a routine practice for all facilities which process medical and surgical instruments.

 

 

Friday, September 6, 2013

Trust, But Verify


You Could Look It Up


Many medical manufacturers employ clinical specialists – or nurse clinicians – to assist in the sales process. The idea is that anyone with RN or BSN behind his or her name brings instant street cred to the avaricious sales rep in the healthcare environment.
Still, there are times when the clinicians may not know exactly What the Hell They Are Talking About!

Such a situation comes to mind.
 STERIS Corporation had introduced a new line of Chemical Indicators, Chemical Integrators and Biological Indicators to the sterile processing market.  The clinical specialists were dispatched to the field to grant gravitas to the sales reps and jump start our sales.
Sue, a woman I admired despite her heavy smoking and ceaseless monologue, had come to town to work with me.  She had years of hospital experience behind her, including stints as a charge nurse and OR Director. She had logged clinical specialist time in wound care and disinfection.  She had street cred to spare.

One of the goals of a sales rep – tertiary to “Exceed Quota” and “What Have You Done for Us Lately” -- is to become a “Trusted Advisor” to the customer.  This means that the customer trusts the sales rep enough, through a history of honesty and cooperation, to let him/her in the door to hear a new pitch.
The best customers for the clinical specialist to shill are the ones where the rep is a Trusted Advisor, and where the customer is currently using a competitor’s product.  I set up appointments with several such customers over a three-day period.
Three appointments into the first day, my Trusted Advisor halo was becoming tarnished. How to broach this to Sue?
“Sue,” I said, “I’m not comfortable with your directions for using biological indicators in the autoclave.”
“What do you mean” said Sue. “What’s the problem?”
“It’s wrong.  You’re telling them to run their daily BIs in an empty chamber. That’s not right. They should be run in a full chamber, with instruments.”
“No they shouldn’t, they should be run in an empty chamber.”
“I don’t think so. AAMI (Association for the Advancement of Medical Instrumentation – or ‘God’ in the OR & Sterile Processing) says to run the daily with a load.”
“No it doesn’t.  I’m sure of it.”
I dropped it, but I could see the lines of self-doubt stealing across her face. She went to her clinical cheat sheet as I navigated the two-lane. She studied. She flipped pages. She blanched. She looked at me.
“Oh, my god,” she said. “I have been telling them the wrong thing. I can’t believe it.”
Sue began pulling recently acquired business cards from her portfolio and dialing her cell phone. She was calling the customers we had just visited to issue a mea culpa and convey the correct information. It was late enough in the day that she was unsuccessful in reaching them. But her follow-up e-mails were contrite and effective.
So what’s the takeaway here? No matter how much alphabet soup follows a clinician’s or sales rep’s name, they may still be in error. Protect yourself. Verify the information.
Short story masters James Thurber and Ring Lardner advise that “You could look it up.”
AAMI’s guidelines recommend that  BIs (within a PCD*) :
·         May be used to monitor nonimplant loads

·         Should  be used in every load containing implants

·         Should be used for weekly, preferably daily, routine efficacy testing

·         Should be run in a full load for wrapped items

And for sterilizer qualification testing (following installation, relocation, major repairs, etc.):

·         Should be run three times consecutively in an empty chamber;

·         Except for table-top sterilizers, where they should be run three times consecutively in a full load.

* AAMI 2.97 – PCD – Process Challenge Device. Item designed to constitute a defined resistance to a sterilization process and used to assess performance of the process.

But don’t take my word for it. You Could Look It Up!!


Wednesday, August 28, 2013

Lessons Learned

The Fire Alarm

I’m the guy that set off the fire alarm.

It was impressive how quickly the contractor, security and assorted hospital personnel responded.  Within seconds they came piling into the room, swimming through the steam, accompanied by the AAANK! AAANK! AAANK! of the fire horn and the fervent blinking of the red alarm lights.
I stood in the middle of the room, hands above my head, waving my arms.

“It was me!” I shouted. “False alarm.  The water was turned off to the sterilizer. I have shut it down. False alarm!”
This cheery explanation did little to stanch the hostility.  While my quick confession deflected a good chewing out, I remained wary of a well-aimed wrench to the back of my head.

Professional truck and motor coach drivers pre-trip their vehicles every day before hitting the road. They don’t rely only on the readings of the instrument panel. They check fluid levels, belts and hoses, tire condition (both tread and sidewall), mirror mounts, windshield wipers, brakes and so much more.

Anyone servicing or starting up a steam sterilizer should follow a similar pre-trip protocol prior to running a cycle.

Here’s what happened:

A rural Middle Tennessee hospital was expanding its Surgery and Sterile Processing areas. In addition to building several state-of-the-art OR suites, they included a central sterile core for supply storage and reprocessing of instruments. The equipment had been installed and the storage shelves were being assembled. It was time to test the equipment.

Sterile processing equipment in the sterile core included three Century V-116 autoclaves and three SYSTEM 1 low temperature sterilizers.

An autoclave is nothing more than a box into which steam is injected and then removed with the aim of sterilizing instruments. Pretty simple. It needs three utilities to operate: electricity, steam and cold water.  Electricity is used to operate the controls and solenoids. Steam is used to sterilize the instruments. Cold water serves two functions – first, it spins through a valve to create a vacuum and evacuate the sterilizer; second, it cools the steam and vapor effluent to a temperature low enough to pass codes and enter the sanitary sewer – usually less than 160 deg. Fahrenheit.


The Century V-116 autoclave is a workhorse – easy to operate, reliable and forgiving.  In the scenario above, the steam line dropped from the ceiling and the water line came in at the floor.  Both lines open and close with the use of a ball valve. When the handle to the ball valve is parallel to the feed line, the line is open. When it is perpendicular to the feed line, the line is closed.

The steam line and its yellow handle were easy to see from the floor. Yellow handle parallel to the steam line – therefore open.  The water line was hidden behind the cabinet of the autoclave. Rather than take a little time to check the water line, I ASSUMED it was also on. Bad mistake.

The sterile core emptied out at lunch time, leaving me alone with my sterilizers. I powered up one of the V-116s, shut the chamber door and started a cycle. The unit made its “chunk, chunk, chunk” sound as the gasket inflated to seal the door. The autoclave began its conditioning phase, which involves filling and emptying with steam. The fill part went well, steam line hissing and temperature rising. The emptying part not so well. With no cold water to pull the vacuum or cool the effluent, steam came rolling back up out of the drain pipe and filled the room. The heat sensors, faithful to their mission, triggered the fire alarm.

I knew immediately what the problem was and aborted the cycle, which was small comfort as the responders rushed into the room.

Here’s what I should have done: Follow the checklist. You can find it in the operator’s manual. And keep the operator’s manual with the machine. Too many times the manual is stored in a location that no one can remember and cannot be found. Having the manual in close proximity to the equipment may well prevent a call to maintenance or a service technician to address what may have been an easy fix.

And assume nothing!